BACKGROUND: Measurable residual disease (MRD) monitoring in acute lymphoblastic leukemia (ALL) is an important predictive factor for patient outcome and treatment intensification. Molecular monitoring, particularly with quantitative polymerase chain reaction (qPCR) to measure immunoglobin heavy or kappa chain (Ig) or T-cell receptor (TCR) gene rearrangements, offers high sensitivity but accessibility is limited by expertise, cost, and turnaround time. Flow cytometric assays are cheaper and more widely available, and sensitivity is improved with multi-parameter flow cytometry at eight or more colors. METHODS: We developed a 10-color single tube flow cytometry assay. Samples were subject to bulk ammonium chloride lysis to maximize cell yields with a target of 1 x 10(6) events. Once normal maturation patterns were established, patient samples were analyzed in parallel to standard molecular monitoring. RESULTS: Flow cytometry was performed on 114 samples. An informative immunophenotype was identifiable in all 22 patients who had a diagnostic sample. MRD analysis was performed on 87 samples. The median lower limits of detection and quantification were 0.004% (range 0.0005%-0.028%) and 0.01% (range 0.001%-0.07%) respectively. Sixty-five samples had concurrent molecular MRD testing, with good correlation (r = 0.83, p < 0.001). Results were concordant in 52 samples, and discordant in 13 samples, including one case where impending relapse was detected by flow cytometry but not Ig/TCR qPCR. CONCLUSIONS: Our 10-color flow cytometric MRD assay provided adequate sensitivity and good correlation with molecular assays. This technique offers rapid and affordable testing in B-ALL patients, including cases where a suitable molecular assay cannot be developed or has reduced sensitivity.
Publisher
Wiley
Keywords
Acute Disease; Adult; Flow Cytometry/methods; Humans; Immunophenotyping; Neoplasm, Residual/diagnosis/genetics; *Precursor Cell Lymphoblastic Leukemia-Lymphoma/diagnosis/genetics; Receptors, Antigen, T-Cell; B-all; Mrd; flow cytometry; immunophenotype; molecular
Department(s)
Pathology; Haematology
PubMed ID
34806309
Terms of Use/Rights Notice
Refer to copyright notice on published article.


Creation Date: 2025-04-04 05:25:04
Last Modified: 2025-04-04 05:39:07

© 2025 The Walter and Eliza Hall Institute of Medical Research. Access to this website is subject to our Privacy Policy and Terms of Use

An error has occurred. This application may no longer respond until reloaded. Reload 🗙