Abstract
PURPOSE: The TROG 13.01 (SAFRON II) trial was a phase 2 multicenter trial comparing single-fraction (SF) and multifraction (MF) stereotactic body radiation therapy. Patients with 1 to 3 peripheral pulmonary oligometastases were randomized 1:1 between 28 Gy in 1 fraction and 48 Gy in 4 fractions. There were no differences between arms in efficacy or toxicity. We performed an analysis to assess changes in pulmonary function tests (PFTs) between arms over time and assessed the effect of the number and total volume of targets on PFT change over time. METHODS AND MATERIALS: A linear mixed model was used to describe the PFTs by treatment arm over time. The effect of number and volume of targets on PFTs at 6 and 12 months was assessed by a simple linear model. RESULTS: Ninety patients were randomized; 87 were treated for 133 pulmonary oligometastases. Forty-four were randomized to the SF arm and 43 to the MF arm. There were no differences in absolute or relative PFT measures of forced expiratory volume in 1 second (FEV(1)), diffusing capacity of the lungs for carbon monoxide (DLCO), or forced vital capacity (FVC) between the 2 arms. At 12 months, there was a reduction in absolute DLCO from baseline (-1.7 mL/min/mm Hg [95% CI, -2.5 to -1.0]), relative DLCO (-5.5% [95% CI, -8.4% to -2.6%]), absolute FEV(1) (-0.17 L [95% CI, -0.23 to -0.11]), and absolute FVC (-0.20 L [95% CI, -0.27 to -0.13]). In patients with multiple pulmonary targets, increase in target number (per lesion) was associated with a reduction in the absolute FEV(1) at 6 months of -0.10 L (95% CI, -0.18 to -0.03; P = .007), FEV(1) at 12 months of -0.10 L (95% CI, -0.20 to -0.01; P = .04), FVC at 6 months of -0.11 L (95% CI, -0.20 to -0.03; P = .014), and FVC at 24 months of -0.13 L (95% CI, -0.25 to -0.01; P = .036). Reduction in FEV(1) was also seen per 10-mL increase in PTV at 12 months (-0.03 L [95% CI, -0.06 to -0.00], P = .036). The number of targets and PTV were not associated with DLCO. CONCLUSIONS: Treating multiple targets resulted in increased loss of FEV(1) and FVC but not DLCO. There were no significant differences in PFT decline between SF and MF stereotactic body radiation therapy.
Publisher
Elsevier
Keywords
Humans; *Lung; *Lung Diseases; Forced Expiratory Volume; Vital Capacity; Respiratory Function Tests
Department(s)
Physical Sciences; Biostatistics and Clinical Trials; AYA Cancer Service; Radiation Oncology
Terms of Use/Rights Notice
Refer to copyright notice on published article.


Creation Date: 2024-03-28 06:51:21
Last Modified: 2024-03-28 06:51:29

© 2024 The Walter and Eliza Hall Institute of Medical Research. Access to this website is subject to our Privacy Policy and Terms of Use

An error has occurred. This application may no longer respond until reloaded. Reload 🗙